Emergency surgery following failed PDA device closure- A case report


  • #CH/ADU 01-EP-8
  • Congenital Heart Surgery/Adult Congenital Cardiac. E-POSTER (ORAL) SESSION
  • E-Poster (oral)

Emergency surgery following failed PDA device closure- A case report

Raghav Johari, Deepak Tiwari, Muneesh Batheja

NIMS super- speacility hospital, Jaipur , India

Date, time and location: 2018.05.26 15:30, Exhibition area, 1st Floor. Zone – D

Abstract

Emergency surgery - Following failed PDA device closure  - A case report

Objective- Although PDA device closure is a safe treatment of choice, but in emergency surgery remains gold standard.

Methods- 12 year old boy was taken for emergency PDA ligation and device retreval, who had failed device closure resulting in device migrating to LPA.


Results- device was retrieved, pda ligated.. patient was discharged on post-operative day 4.

Conclusion- sizing devise for PDA, is very important, and should be done by experienced operators. Else it can b life threatening.